The VE.Bus BMS V2 is a Battery Management System (BMS) designed to interface with and protect a single, or multiple Victron Lithium Battery Smart 12,8V & 25,6V (LiFePO4 or LFP) in systems that have Victron inverters or inverter/chargers with VE.Bus communication. It monitors and protects the batteries against over voltage and under voltage of any individual cell, and also over temperature or under temperature conditions.Based on the status of the battery or batteries, the BMS will:Generate a pre-alarm signal to alert of an imminent cell under voltage condition.Disable inverting in VE.Bus inverters or inverter/chargers via VE.Bus, and disable other loads via the 'Load Disconnect' terminal in the event of a cell under voltage condition.Disable charging in VE.Bus inverters or inverter/chargers via VE.Bus and disable other chargers via the 'Charge Disconnect' terminal in the event of a cell overvoltage, under temperature or over temperature condition.Remote on/off terminals.Ability to disable VE.Direct and VE.Can solar chargers via a GX device.Allowing control of the VE.Bus inverter/charger from multiple devices, like the Digital Multi Control, the VE.Bus Smart dongle and/or a GX device.Auxiliary power input and output terminals that allow a GX device to remain powered in the event of a system shutdown.
Dimensions (L x W x H mm)200 x 55 x 125 mm
DC Input Operating Voltage Range[9, 70] V
Current Draw Regular10 mA
Current Draw Low2 mA
Current Draw Off1.5 mA
Aux Input Current Rating1 A
Gx Power Current Rating1 A
Load Disconnect Output Source1 mA
Charge Disconnect Output Source1 mA
Pre Alarm OutputNormally free floating - In case of alarm: output voltage Vbat -0.1 V
Pre Alarm Current Rating1 A
Remote TerminalsUsage modes to turn the system on or off: a) ON when the L and H terminal are interconnected (switch or relay contact) b) ON when the L terminal is pulled to battery minus (V<3.5 V) c) ON when the H terminal is high (2.9 V < VH < Vbat) d) OFF in all other conditions
Max Humidity95 %
Battery Communication TerminalsTerminals with M8 circular connectors
Input Output TerminalsScrew terminals
Vebus Terminals2 x RJ45 sockets to connect to all VE.Bus products
Power Supply CableRecommended fuse size 0.3 A - 2.5 (dependent on devices connected to Load disconnect and pre-alarm output)
MaterialABS
ColourMatt black with a blue sticker
Protection CategoryIP20
Weight0.12 kg
Height23.8 mm
Width94.5 mm
Depth10.5 mm
SafetyEN 60950
EmissionEN 55014-1,EN-IEC 61000-6-3
ImmunityEN 55014-2,EN-IEC 61000-6-1, EN-IEC 61000-6-2
AutomotiveEN 50498
SKUBMS300200200